top of page
< Back

Mutoh VJ-1324 — E 065Err PF motor

VJ-1324

< Back

Mutoh VJ-1324 — E 065Err PF motor

E 065Err PF motor

Abnormal
condition in PF
motor (X-axis)
during printer
operation.
Displayed if the
difference
between motor
command value
and feedback
from encoder is
large.

Checks / troubleshooting:
1. Check error history from "Test: Record" of self-diagnosis
function.
2. Set the number of endurance running cycles to 50 or
more from "Life: PF motor" of self-diagnosis function,
and check if "PF motor error" occurs.
3. Check "Encoder: PF" from "Test: Encoder" of self-
diagnosis function.
4. Is the area around PF encoder contaminated?
5. Check if MAIN Power Board normally supplies DC24V.
6. PF motor Assy may be damaged.
7. MAIN board Assy may be defective.

• 6. PF motor Assy may be damaged

VJ-1324X; VJ-1638UH

VJ-1324

bottom of page