top of page
< Back

Mutoh VJ-1324X — E 067Err PF encoder

VJ-1324X

< Back

Mutoh VJ-1324X — E 067Err PF encoder

E 067Err PF encoder

Abnormal
condition in
media feed
amount (X-axis)
during printer
operation.
Displayed if
there is no
feedback from
encoder.

Checks / troubleshooting:
1. Check error history from "Test7: Record" of self-
diagnosis function.
2. Set the number of endurance running cycles to 50 or
more from "Life: PF motor" of self-diagnosis function,
and check if "PF encoder error" occurs.
3. Check "Encoder: PF" from "Test5: Encoder" of self-
diagnosis function.
4. Is the area around PF encoder contaminated?
5. Check if MAIN Power Board normally supplies DC24V.
6. PF motor Assy may be damaged.
7. MAIN board Assy may be defective.

• 6. PF motor Assy may be damaged

VJ-1324; VJ-1638UH

VJ-1324X