top of page
< Back

Mutoh VJ-1324X — E072 Err CR Current E074 Err CR2 Current E092 Err CR Over Load

VJ-1324X

< Back

Mutoh VJ-1324X — E072 Err CR Current E074 Err CR2 Current E092 Err CR Over Load

E072 Err CR Current E074 Err CR2 Current E092 Err CR Over Load

An overload
condition is
detected in CR
motor (Y-axis)
during printer
operation.

Checks / troubleshooting:
1. Check error history from "Test: Record" of self-diagnosis
function.
2. Move carriage in both directions while the printer is
turned off, and check if there is any position where
carriage does not move smoothly.
3. Set the number of endurance running cycles to 50 or
more from "Life1 : CR motor" of self-diagnosis function,
and check if "CR Current" or “CR2 current” occurs.
4. Check if T fence is contaminated or worn out.
5. Check "Encoder: CR" from "Check: Test” -"Test5:
Encoder" of self-diagnosis function.

​

VJ-1324; VJ-1324X

VJ-1324X

bottom of page