Mutoh VJ-1324X — E090 Err Heater Volt.
VJ-1324X
Mutoh VJ-1324X — E090 Err Heater Volt.
E090 Err Heater Volt.
Displayed when
voltage exceeds
the threshold
level of 200V
start up even
though the
printer was
started with the
voltage of 100V
on HEATER
CONT board
Assy .
Checks / troubleshooting:
• Input voltage from AC inlet or HEATER CONTROL
board Assy may be malfunctioning.
Recommended actions:
1. Connect two power cables(for MAIN and for
HEATER) to separate outlets.
2. Check the connection of HEATER CONT
board Assy.
3. Replace HEATER CONT board Assy .
• board Assy may be malfunctioning
VJ-1324; VJ-1324X; VJ-1624; VJ-1624X
VJ-1324X