top of page
< Back

Mutoh VJ-1324X — E148 Err Serial Comp

VJ-1324X

< Back

Mutoh VJ-1324X — E148 Err Serial Comp

E148 Err Serial Comp

A data read in
by serial
communication
between MAIN
board Assy and
CR board Assy
is different from
the required
one.

Checks / troubleshooting:
1. CR FFC’s connection may be faulty or it may be
damaged.
2. CR board Assy may be malfunctioning.
3. MAIN board Assy may be malfunctioning.

Recommended actions:
1. Restart the printer to see if the same error
still occurs
2. Check the connection of CR FFC.
3. Replace CR FFC.
4. Replace CR board Assy .
5. Replace MAIN board Assy .

• 2. CR board Assy may be malfunctioning
• 3. MAIN board Assy may be malfunctioning

VJ-1324; VJ-1324X; VJ-1624; VJ-1624X

VJ-1324X