top of page
Mutoh VJ-1624 — E081 Err CR Origin
VJ-1624
Mutoh VJ-1624 — E081 Err CR Origin
E081 Err CR Origin
CR_HP cannot be
detected.
Checks / troubleshooting:
1. Check CR origin sensor in “Sen.1: CR
Origin” in the self-diagnosis function.
(Check if “ON” is displayed when Carriage is
locked and “OFF” is displayed when
Carriage is moved.)
2. CR origin sensor may be damaged.
3. Check the connection of MAIN board Assy .
4. MAIN board Assy may be damaged.
Recommended actions:
Check connection of CR origin sensor cable Assy
connector.
• 2. CR origin sensor may be damaged
• 4. MAIN board Assy may be damaged
VJ-426UF; VJ-626UF; VJ-628; VJ-628M; VJ-1324; VJ-1324X; VJ-1604X; VJ-1624; VJ-1624X; VJ-1627MH; VJ-1628MH; VJ-1638UH; VJ-1638UR; XPJ-461UF; VJ-1638X / VJ-1638WX; VJ-2638X
VJ-1624