Mutoh VJ-1624 — E144 Err Serial WR
VJ-1624
Mutoh VJ-1624 — E144 Err Serial WR
E144 Err Serial WR
Failure is detected
during serial
communication writing
between MAIN board
Assy and CR board
Assy.
Checks / troubleshooting:
1. CR FFC’s connection may be faulty or it may
be damaged.
2. CR board Assy may be malfunctioning.
3. MAIN board Assy may be malfunctioning.
Recommended actions:
1. Make sure to connect thermistor connector
securely.
2. Replace Thermistor.
3. Replace HEATER CONT board Assy.
1. Restart the printer to see if the same error
still occurs.
<
2. Check the connection of CR FFC.
3. Replace CR FFC.
4. Replace CR board Assy.
5. Replace MAIN board Assy.
• 2. CR board Assy may be malfunctioning
• 3. MAIN board Assy may be malfunctioning
VJ-1324; VJ-1324X; VJ-1624; VJ-1624X; VJ-1627MH; VJ-1628MH