top of page
< Back

Mutoh VJ-1624 — Full wasteInkTank

VJ-1624

< Back

Mutoh VJ-1624 — Full wasteInkTank

Full wasteInkTank

Waste fluid bottle is full.

Checks / troubleshooting:
1. Check if Waste fluid bottle is full.
2. Check the connection of the connector of
Waste fluid level switch.
3. Waste fluid level switch may be damaged.
4. Check JUNCTION board Assy.

Recommended actions:
Dispose of waste fluid.

• 3. Waste fluid level switch may be damaged

VJ-1604X; VJ-1624X; VJ-1627MH; VJ-1628MH; VJ-1638UH; VJ-1638X / VJ-1638WX; VJ-2638X; VJ-628; VJ-628M

VJ-1624