top of page
Mutoh VJ-1624X — E145 Err Serial RD
VJ-1624X
Mutoh VJ-1624X — E145 Err Serial RD
E145 Err Serial RD
Failure is detected
during serial
communication reading
between MAIN board
Assy and CR board
Assy.
Recommended actions:
1. Make sure to connect thermistor connector
securely.
2. Replace Thermistor.
3. Replace HEATER CONT board Assy.
1. Restart the printer to see if the same error
still occurs.
<
2. Check the connection of CR FFC.
3. Replace CR FFC.
4. Replace CR board Assy.
5. Replace MAIN board Assy.
VJ-1324; VJ-1324X; VJ-1624; VJ-1624X; VJ-1627MH; VJ-1628MH; VJ-1638UH; VJ-2638X
VJ-1624X
bottom of page