Mutoh VJ-1627MH — E069 Err PF Timeout
VJ-1627MH
Mutoh VJ-1627MH — E069 Err PF Timeout
E069 Err PF Timeout
An anomaly is
detected in media
feed amount (X-axis)
during printer
operation.
Displayed when Grid
roller has not reached
designated position.
Checks / troubleshooting:
1. Check error record in “Test : Record” in
self-diagnosis function.
2. Set endurance time to more than 50
times in “Life: PF Motor” in self-
diagnosis function to see if any errors
related to PF motor such as “PF motor
error” occurs.
3. Check “Encoder: PF” in “Check: Test” –
“Test: Encoder” in self-diagnosis
function.
• Turn PF connecting axle by hand and
see if value displayed on panel
changes as follows.
• Front feed direction: Increase
• Back feed direction: Decrease
4. PF encoder may be damaged.
5. PF encoder may be damaged.
6. MAIN board may be damaged.
Recommended actions:
Check connection of following connectors of
MAIN board .
• PF motor cable connector
• PF_ENC connector:
• Connector that is connecting PF
motor and PF motor relay
• Replace PF encoder.
• If Main power board is damaged,
Replace.
• Replace PF motor.
• Replace MAIN board.
• 4. PF encoder may be damaged
• 5. PF encoder may be damaged
• 6. MAIN board may be damaged
• PF encoder
• PF motor
• MAIN board
VJ-426UF; VJ-626UF; VJ-628; VJ-628M; VJ-1324; VJ-1324X; VJ-1604X; VJ-1624; VJ-1624X; VJ-1627MH; VJ-1628MH; VJ-1638UH; VJ-1638UR; XPJ-461UF; VJ-1638X / VJ-1638WX; VJ-2638X
VJ-1627MH