top of page
< Back

Mutoh VJ-1627MH — E073 Err PF2 Current

VJ-1627MH

< Back

Mutoh VJ-1627MH — E073 Err PF2 Current

E073 Err PF2 Current

An overload condition
is detected in PF
motor (X-axis) during
printer operation.

Checks / troubleshooting:
1. Is weight of media used within
recommended weight?
2. Is there paper jam around Grid roller?
3. Check error record in “Test : Record” in
self-diagnosis function.
4. Set endurance time to more than 50
times in “Life: PF Motor” in self-
diagnosis function to see if any errors
related to PF motor such as “PF motor
error” occurs.
5. Check “Encoder: PF” in “Check: Test” –
“Test5: Encoder” in self-diagnosis
function.
• Turn PF connecting axle by hand and
see if value displayed on panel
changes as follows.
• Front feed direction: Increase
• Back feed direction: Decrease
6. PF encoder may be damaged.
7. PF motor may be damaged.
8. Power board may be damaged.
9. MAIN board may be damaged.

Recommended actions:
• Explain user about recommended
media weight.
• Remove paper jam, check if Media
holder and Print head are damaged,
and check if same error occurs.
Check connection of following connectors of
MAIN board .
• PF motor cable connector
• PF_ENC connector
• Connector that is connecting PF
motor and PF motor relay
• Replace PF encoder.
• Replace PF motor .
• Replace Power board.
• Replace MAIN board .

• 6. PF encoder may be damaged
• 7. PF motor may be damaged
• 8. Power board may be damaged
• 9. MAIN board may be damaged
• PF encoder
• PF motor
• Power board
• MAIN board

VJ-1627MH; VJ-1628MH; VJ-1638UH

VJ-1627MH

bottom of page