Mutoh VJ-1627MH — E081 Err CR Origin
VJ-1627MH
Mutoh VJ-1627MH — E081 Err CR Origin
E081 Err CR Origin
CR origin cannot be
detected.
Checks / troubleshooting:
1. Check CR origin sensor in “Sen.: CR
Origin” in self-diagnosis function.
(Check if “ON” is displayed when
Carriage is locked and “OFF” is
displayed when Carriage is moved.)
2. CR origin sensor may be damaged.
3. JUNCTION board may be damaged.
Recommended actions:
Check connection of CR origin sensor cable
connector.
• 2. CR origin sensor may be damaged
• 3. JUNCTION board may be damaged
VJ-426UF; VJ-626UF; VJ-628; VJ-628M; VJ-1324; VJ-1324X; VJ-1604X; VJ-1624; VJ-1624X; VJ-1627MH; VJ-1628MH; VJ-1638UH; VJ-1638UR; XPJ-461UF; VJ-1638X / VJ-1638WX; VJ-2638X