Mutoh VJ-1628MH — E125 Err P Height Sns
VJ-1628MH
Mutoh VJ-1628MH — E125 Err P Height Sns
E125 Err P Height Sns
An anomaly is detected in Media thickness
detection sensor
Checks / troubleshooting:
Check if Solenoid at media detection area is
operating properly when detecting media
thickness.
Check connection of Media thickness
detection solenoid relay connector.
Check connection of Media thickness
detection sensor connector.
Check connection of CR_FFC.
Media thickness detection sensor may be
malfunctioning.
CR_FFC may be damaged.
CR board may be damaged.
MAIN board may be damaged.
Recommended actions:
If it is malfunctioning, replace Media
thickness detection solenoid.
• CR_FFC may be damaged
• CR board may be damaged
• MAIN board may be damaged
VJ-1627MH; VJ-1628MH; VJ-1638UH