top of page
< Back

Mutoh VJ-1628MH — E125 Err P Height Sns

VJ-1628MH

< Back

Mutoh VJ-1628MH — E125 Err P Height Sns

E125 Err P Height Sns

An anomaly is detected in Media thickness
detection sensor

Checks / troubleshooting:
Check if Solenoid at media detection area is
operating properly when detecting media
thickness.
Check connection of Media thickness
detection solenoid relay connector.
Check connection of Media thickness
detection sensor connector.
Check connection of CR_FFC.
Media thickness detection sensor may be
malfunctioning.
CR_FFC may be damaged.
CR board may be damaged.
MAIN board may be damaged.

Recommended actions:
If it is malfunctioning, replace Media
thickness detection solenoid.

• CR_FFC may be damaged
• CR board may be damaged
• MAIN board may be damaged

VJ-1627MH; VJ-1628MH; VJ-1638UH

VJ-1628MH

bottom of page