top of page
Mutoh VJ-1638UH — E081 Err CR Origin
VJ-1638UH
Mutoh VJ-1638UH — E081 Err CR Origin
E081 Err CR Origin
CR_HP cannot be detected.
Checks / troubleshooting:
1. Check CR origin sensor in “Sen.: CR Origin”
in the self-diagnosis function.
(Check if “ON” is displayed when Carriage is
locked and “OFF” is displayed when
Carriage is moved.)
2. CR origin sensor may be malfunction.
3. MAIN board may be malfunction.
Recommended actions:
Check connection of CR origin sensor cable
connector.
• 2. CR origin sensor may be malfunction
• 3. MAIN board may be malfunction
VJ-426UF; VJ-626UF; VJ-628; VJ-628M; VJ-1324; VJ-1324X; VJ-1604X; VJ-1624; VJ-1624X; VJ-1627MH; VJ-1628MH; VJ-1638UH; VJ-1638UR; XPJ-461UF; VJ-1638X / VJ-1638WX; VJ-2638X