top of page
< Back

Mutoh VJ-1638UH — E125 Err P Height Sns

VJ-1638UH

< Back

Mutoh VJ-1638UH — E125 Err P Height Sns

E125 Err P Height Sns

An anomaly is detected in
Media thickness detection
sensor

Checks / troubleshooting:
1. Check if Solenoid at media detection area is
operating properly when detecting the media
thickness.
2. Check the connection of Media thickness
detection solenoid relay connector.
3. Check the connection of Media thickness
detection sensor connector.
4. Check the connection of CR_FFC.
5. Media thickness detection sensor may be
malfunctioning.
6. CR_FFC may be malfunction.
7. CR board may be malfunction.
8. MAIN board may be malfunction.

Recommended actions:
If it is malfunctioning, replace Media thickness
detection solenoid.

• 6. CR_FFC may be malfunction
• 7. CR board may be malfunction
• 8. MAIN board may be malfunction

VJ-1627MH; VJ-1628MH; VJ-1638UH

VJ-1638UH

bottom of page