Mutoh VJ-1638X / VJ-1638WX — E142Err After heat Th.
VJ-1638X / VJ-1638WX
Mutoh VJ-1638X / VJ-1638WX — E142Err After heat Th.
E142Err After heat Th.
An anomaly is detected
in After Thermistor.
Checks / troubleshooting:
1. After Thermistor connector may be
malfunctioning.
2. After Thermistor may be disconnecting.
3. HEATER CONT board may be
malfunctioning.
Recommended actions:
1. Make sure to connect thermistor connector
securely.
2. Replace Thermistor relay.
3. Replace HEATER CONT board.
1. After Thermistor connector may be
malfunctioning.
2. After Thermistor may be disconnecting.
3. HEATER CONT board may be
malfunctioning.