Mutoh VJ-2638X — E176~E183 Err Subtank Hi() One of the letters from KkCcMmYy is displayed in the parentheses.

VJ-2638X

< Back

Mutoh VJ-2638X — E176~E183 Err Subtank Hi() One of the letters from KkCcMmYy is displayed in the parentheses.

E176~E183 Err Subtank Hi() One of the letters from KkCcMmYy is displayed in the parentheses.

An anomaly is detected
in Subtank Hi Sensor.

Checks / troubleshooting:
1. Subtank Hi sensor may be malfunction.
2. 2 way solenoid may be malfunction.
3. JUNCTION board may be malfunction.

Recommended actions:
1. Replace Subtank Assy.
2. Replace 2 way solenoid.
3. Replace JUNCTION board.

• 1. Subtank Hi sensor may be malfunction
• 2. 2 way solenoid may be malfunction
• 3. JUNCTION board may be malfunction