Mutoh VJ-426UF — E070 Err CR Timeout (Continuted)
VJ-426UF
Mutoh VJ-426UF — E070 Err CR Timeout (Continuted)
E070 Err CR Timeout (Continuted)
A timeout is detected in
the Head shift amount
(Y-axis) during printer
operation.
Displayed when
Carriage has not
reached the designated
position.
Checks / troubleshooting:
6. Check “Encoder: CR” in “Check: Test” –
“Test: Encoder” in the self-diagnosis
function.
• Move Carriage to see if the values on the
panel increases/decreases as follows.
• CW direction: Increase
• CCW direction: Decrease
7. Carriage lock solenoid may be damaged.
(Check if “ON” is displayed when Carriage is
locked and “OFF” is displayed when
Carriage is moved in “Sen.: CR Origin” in the
self-diagnosis function.)
8. MAIN board may be damaged.
Head FFC may be damaged.
Head thermistor may be damaged.
Recommended actions:
When NG:
a) Check the cable connection at the following
places.
• CR board connector
b) Replace the following parts.
• CR encoder
• T fence
• CR motor
• CR_FFC
• CR board
• 7. Carriage lock solenoid may be damaged
• 8. MAIN board may be damaged
• Head FFC may be damaged
• Head thermistor may be damaged
VJ-426UF; VJ-626UF; VJ-628; VJ-628M; VJ-1604X; VJ-1624; VJ-1624X; VJ-1627MH; VJ-1638UR; XPJ-461UF; VJ-1638X / VJ-1638WX; VJ-2638X
VJ-426UF