Mutoh VJ-426UF — E241Err PG Limit
VJ-426UF
Mutoh VJ-426UF — E241Err PG Limit
E241Err PG Limit
It means that the heights
of the lifting table is not
detected.
Checks / troubleshooting:
1. Laser sensor cable may have unplugged.
2. Laser sensor may be damaged.
3. MAIN board may be damaged.
Recommended actions:
Plug Laser sensor cable securely.
Replace Laser sensor.
• 2. Laser sensor may be damaged
• 3. MAIN board may be damaged
• Laser sensor
VJ-626UF; XPJ-461UF
VJ-426UF
bottom of page