Mutoh VJ-628 — E141Err Platen heat Th.

E141Err Platen heat Th.

An anomaly is detected
in Platen Thermistor.

Checks / troubleshooting:
1. Platen Thermistor connector may be
malfunctioning.
2. Platen Thermistor may be disconnecting.
3. HEATER DRIVE board may be
malfunctioning.

Recommended actions:
1. Make sure to connect thermistor connector
securely.
2. Replace Thermistor relay.
3. Replace DRIVE board.

​