Mutoh VJ-628M — E071 Err PF Current E073 Err PF2 Current
VJ-628M
Mutoh VJ-628M — E071 Err PF Current E073 Err PF2 Current
E071 Err PF Current E073 Err PF2 Current
An overload condition is
detected in PF motor (X-
axis) during printer
operation.
Checks / troubleshooting:
1. Is weight of media used within
recommended weight?
2. Is there paper jam around Grid roller?
3. Check error record in [Test : Life] in self-
diagnosis function.
4. Set endurance time to more than 50 times in
[Life: PF Motor] in self-diagnosis function to
see if any errors related to PF motor such as
[PF motor error] occurs.
5. Check [Encoder: PF] in [Check: Test] –
[Test5: Encoder] in self-diagnosis function.
• Turn PF connecting axle by hand and see
if value displayed on panel changes as
follows.
• Front feed direction: Increase
• Back feed direction: Decrease
6. PF encoder may be damaged.
7. PF motor may be damaged.
8. Power board may be damaged.
9. MAIN board may be damaged.
Recommended actions:
• Explain user about recommended media
weight.
• Remove paper jam, check if Media holder
and Head are damaged, and check if
same error occurs.
Check connection of following connectors of
MAIN board .
• PF motor cable connector
• PF_ENC connector
• Connector that is connecting PF
motor and PF motor relay
• Replace PF encoder.
• Replace PF motor.
• Replace Power board.
• Replace MAIN board.
• 6. PF encoder may be damaged
• 7. PF motor may be damaged
• 8. Power board may be damaged
• 9. MAIN board may be damaged
• PF encoder
• PF motor
• Power board
• MAIN board
VJ-426UF; VJ-626UF; VJ-628; VJ-628M; VJ-1324; VJ-1324X; XPJ-461UF
VJ-628M