Mutoh VJ-628M — E081 Err CR Origin

VJ-628M

< Back

Mutoh VJ-628M — E081 Err CR Origin

E081 Err CR Origin

CR origin cannot be
detected.

Checks / troubleshooting:
1. Check CR origin sensor in [Sen.: CR Origin]
in self-diagnosis function.
(Check if [ON] is displayed when Carriage is
locked and [OFF] is displayed when Carriage
is moved.)
2. CR origin sensor may be damaged.
3. JUNCTION board may be damaged.

Recommended actions:
Check connection of CR origin sensor cable
connector.

• 2. CR origin sensor may be damaged
• 3. JUNCTION board may be damaged

VJ-426UF; VJ-626UF; VJ-628; VJ-628M; VJ-1324; VJ-1324X; VJ-1604X; VJ-1624; VJ-1624X; VJ-1627MH; VJ-1628MH; VJ-1638UH; VJ-1638UR; XPJ-461UF; VJ-1638X / VJ-1638WX; VJ-2638X