top of page
< Back

Mutoh XPJ-461UF — E069 Err PF Timeout

XPJ-461UF

< Back

Mutoh XPJ-461UF — E069 Err PF Timeout

E069 Err PF Timeout

An anomaly is detected
in media feed amount
(X-axis) during printer
operation.
Displayed when Grid
roller has not reached
designated position.

Checks / troubleshooting:
1. Check error record in “Test : Record” in self-
diagnosis function.
2. Set endurance time to more than 50 times in
“Life: PF Motor” in self-diagnosis function to
see if any errors related to PF motor such as
“PF motor error” occurs.
3. Check “Encoder: PF” in “Check: Test” –
“Test: Encoder” in self-diagnosis function.
• Turn PF connecting axle by hand and see
if value displayed on panel changes as
follows.
• Front feed direction: Increase
• Back feed direction: Decrease
4. PF encoder may be damaged.
5. PF encoder may be damaged.
6. MAIN board may be damaged.

Recommended actions:
Check connection of following connectors of
MAIN board .
• PF motor cable connector
• PF_ENC connector:
• Connector that is connecting PF motor and PF
motor relay
• Replace PF encoder.
• If Main power board is damaged, replace
it.
• Replace PF motor.
• Replace MAIN board.

• 4. PF encoder may be damaged
• 5. PF encoder may be damaged
• 6. MAIN board may be damaged
• PF encoder
• PF motor
• MAIN board

VJ-426UF; VJ-626UF; VJ-628; VJ-628M; VJ-1324; VJ-1324X; VJ-1604X; VJ-1624; VJ-1624X; VJ-1627MH; VJ-1628MH; VJ-1638UH; VJ-1638UR; XPJ-461UF; VJ-1638X / VJ-1638WX; VJ-2638X

XPJ-461UF